PCB conductor spacing calculator (IPC-2221)

Minimum spacing between conductors for a peak voltage, from IPC-2221B Table 6-1, for each layer, altitude and coating condition.

Units
Presets
V
DC, or AC peak. 240 V RMS mains is 340 V peak.
Minimum spacing, B2
2.5mm
Table row used
301 to 500 V
Condition
B2: external, uncoated, sea level to 3050 m
IPC-2221B Table 6-1, minimum spacing in mm (voltage is DC or AC peak)
VoltsB1B2B3B4A5A6A7
0 to 150.050.10.10.050.130.130.13
16 to 300.050.10.10.050.130.250.13
31 to 500.10.60.60.130.130.40.13
51 to 1000.10.61.50.130.130.50.13
101 to 1500.20.63.20.40.40.80.4
151 to 1700.21.253.20.40.40.80.4
171 to 2500.21.256.40.40.40.80.4
251 to 3000.21.2512.50.40.40.80.8
301 to 5000.252.512.50.80.81.50.8
Over 500, per V+0.0025+0.005+0.025+0.00305+0.00305+0.00305+0.00305
Method

How this is calculated

V ≤ 500:  spacing = Table 6-1 value for the row containing V
V > 500:  spacing = (301 to 500 V value) + k · (V − 500)
k = 0.0025 (B1), 0.005 (B2), 0.025 (B3), 0.00305 (B4, A5, A6, A7) mm/V
Voltage
DC or AC peak between the two conductors. Mains RMS times 1.414: 120 V is 170 V peak, 240 V is 340 V peak.
Columns
B1 internal; B2 external uncoated to 3050 m; B3 external uncoated above 3050 m; B4 external with permanent polymer coating; A5 external with conformal coating over the assembly; A6 uncoated component leads to 3050 m; A7 conformal coated component leads.
Scope
This is the IPC printed board design spacing. Products under a safety standard (IEC 62368-1, IEC 60664-1) must also meet the creepage and clearance in that standard, which depend on pollution degree, material group and insulation type, and are not reproduced here.
Revision
Values are from Revision B (2012), as reproduced by EMA and Altair. IPC-2221C (December 2023) supersedes it and revises the electrical clearance guidance; its Table 6-1 was not checked here, so confirm against the revision your drawing calls out.
Sources
FAQ

Questions

240 V RMS is 340 V peak, which falls in the 301 to 500 V row: 2.5 mm on an uncoated outer layer (B2), 0.8 mm under a permanent polymer coating (B4), 0.25 mm on an internal layer (B1). A mains product must also meet its safety standard, which usually asks for more.

Clearance is the shortest path through air, creepage the shortest path along the insulating surface. IPC-2221 Table 6-1 gives a single conductor spacing. Product safety standards such as IEC 62368-1 and IEC 60664-1 set the two separately by pollution degree and material group.

Take the 301 to 500 V value and add the per-volt figure for each volt over 500. For an internal layer at 600 V: 0.25 mm + 100 × 0.0025 mm = 0.50 mm. For an uncoated outer layer at 1000 V: 2.5 mm + 500 × 0.005 mm = 5.0 mm.

Air breaks down at a lower voltage as pressure falls. Above 3050 m, column B3 applies to uncoated outer conductors: at 51 to 100 V it asks for 1.5 mm against 0.6 mm at sea level, and 12.5 mm from 251 V. Coating removes the altitude dependence (B4, A5).