Via current calculator

Current one plated via carries for a temperature rise, its resistance, and how many vias in parallel a target current needs.

Units
Presets
mm
µm
IPC-6012 average hole-wall copper: 20 µm Class 2, 25 µm Class 3.
mm
°C
°C
A
Total current the via group must carry.
Current per via at 10 °C rise
1.9A
Hole 0.3 mmLength1.6 mmPlating25 µmPer via, 10 °C rise1.9 A3 vias for 5 A
Section through the via. Hole and board thickness to scale; plating thickness exaggerated.
Vias for 5 A
3
1.67 A each, assuming equal sharing.
Barrel cross-section
0.0255 mm²
Resistance per via
1.14 mΩ
Resistance of 3 in parallel
381 µΩ
Voltage drop across the group
1.91 mV
Power in the group
9.54 mW
Common drill sizes, 25 µm plating, 10 °C rise, 1.6 mm board
Finished holeBarrel (mm²)Current (A)Resistance (mΩ)Vias for 5 A
0.15 mm (5.9 mil)0.01371.212.135
0.20 mm (7.9 mil)0.01771.461.654
0.25 mm (9.8 mil)0.02161.691.353
0.30 mm (11.8 mil)0.02551.901.143
0.35 mm (13.8 mil)0.02952.110.993
0.40 mm (15.7 mil)0.03342.310.883
0.50 mm (19.7 mil)0.04122.690.712
0.60 mm (23.6 mil)0.04913.060.602
0.80 mm (31.5 mil)0.06483.740.452
1.00 mm (39.4 mil)0.08054.370.362
Method

How this is calculated

A = π/4 · ((d + 2p)² − d²) = π · (d + p) · p      d finished hole, p plating
I = 0.048 · ΔT^0.44 · A^0.725                     A in mil², IPC-2221 external
R = ρ20 · (1 + 0.00393 · (T − 20)) · L / A        L board thickness
N = ceil( I_target / I )
Method
IPC-2221 has no via chart. The common approximation treats the barrel as an external conductor of the same cross-section. It is generally conservative: the barrel is short and connects to pads and planes that carry heat away, which the long-trace curve does not credit.
Plating
Default 25 µm, the IPC-6012 Class 3 average hole-wall copper. Class 2 average is 20 µm. Thin-spot minimums are lower (18 µm Class 2, 20 µm Class 3), so a barrel can be locally thinner than the average.
Valid range
Temperature rise 10 to 100 °C and up to 35 A per conductor, as charted in IPC-2221. Equal current sharing between vias is assumed; vias far from the source carry less.
Copper
Resistivity 1.724 × 10⁻⁸ Ω·m at 20 °C (annealed copper, IACS), 0.00393 per °C, evaluated at ambient plus rise.
Sources
FAQ

Questions

With 25 µm plating the barrel is 0.0255 mm², which the IPC-2221 external curve rates at 1.90 A for a 10 °C rise. With 20 µm (Class 2 average) it drops to about 1.6 A. A 5 A rail needs three of them at 25 µm, four at 20 µm, by this method.

The IPC-2221 curve describes a long conductor cooling into still air. A via is only as long as the board is thick, here 1.6 mm, and both ends land on copper that pulls heat out. Measured via temperature rise is usually lower than this predicts, so treat the count as a safe floor.

IPC-6012 requires an average hole-wall copper of 20 µm for Class 2 and 25 µm for Class 3. The calculator defaults to 25 µm. Most prototype fabs build to Class 2 unless you ask, so set 20 µm when the drawing does not call out Class 3.

Usually not for heat, sometimes for regulation. A 0.3 mm via through 1.6 mm of board is about 1.14 mΩ at 35 °C, so three in parallel carrying 5 A drop about 1.9 mV. On a low-voltage, high-current rail that adds to the plane and trace drop.