groundplaneStart a project

Heatsink thermal resistance calculator

The largest heatsink thermal resistance that keeps the junction at its limit, given the power, ambient, the package θJC and the interface material θCS.

Units
Presets
W
°C
Datasheet maximum, less any derating your design rules require.
°C
Air around the heatsink, inside the enclosure.
°C/W
From the device datasheet.
°C/W
From the interface material datasheet. SLVA118A: 0.1 to 1 °C/W typical, up to 5 °C/W with none.
°C/W
Optional. Rated at your airflow. 0 to skip.
Required θSA, maximum
5.5°C/W
Pick a heatsink rated at or below this at your airflow.
Total θJA allowed
7.5 °C/W
Temperature budget
75 °C
Case temperature at the limit
110 °C
Heatsink temperature at the limit
105 °C
Junction with the heatsink entered
110 °C
Required θSA against ambient
02468406080100120Ambient (°C)θSA (°C/W)
Method

How this is calculated

θSA ≤ (T_J − T_A) / P_D − θJC − θCS
θJA = θJC + θCS + θSA
T_case = T_J − P_D · θJC
T_sink = T_A + P_D · θSA
Model
Steady-state series resistances, the thermal analog of Ohm's law (SLVA118A Figure 6). All heat is assumed to leave through the heatsink.
Interface
SLVA118A gives 0.1 to 1 °C/W for common interface materials, up to 5 °C/W with none, and about 0 °C/W for an exposed pad soldered to copper. Use your material's datasheet figure for its thickness and pressure.
Airflow
Heatsink θSA changes with airflow (SLVA462). Compare against the sink's rating at your airflow, in still air if there is no fan.
FAQ

Questions

Divide the temperature budget by the power, then subtract θJC and θCS. 10 W, 125 °C, 50 °C ambient, θJC 1.5 and θCS 0.5 °C/W leaves 5.5 °C/W for the heatsink.

Then no heatsink can hold the junction at the limit: the package and interface already use the whole budget. Reduce power or ambient, use a better interface, or choose a package with lower θJC.

SLVA118A puts common interface materials at 0.1 to 1 °C/W and a dry joint at up to 5 °C/W. At 10 W, the difference between 0.5 and 5 °C/W is 45 °C at the junction.

Use it as a ceiling, not a target. Many design rules derate it; SLVA118A Example 2 derates 125 °C to 115 °C, which cuts the allowed θJA from 39 to 34 °C/W at 1.9 W and 50 °C.

Related
Next step

Designing a board around this? We take it from schematic to bring-up.

Get a board designed