Battery life calculator

Runtime of a duty-cycled load from active and sleep current, wake interval, self-discharge and the capacity you can actually use, with the remaining charge plotted over time.

Presets
mAh
From the cell datasheet, at its stated load and cutoff.
mA
Average current while awake (radio, sensor, MCU).
ms
s
Time from one wake to the next.
µA
Everything left powered while asleep.
%/month
Of rated capacity. 1 % per year is 0.083 % per month.
%
Charge left when the cell falls below your minimum operating voltage. Read it off the discharge curve.
%
Capacity lost at your lowest operating temperature, from the cell datasheet.
Battery life
664.5days
Battery life, years
1.82 years
Average load current
12.99 µA
Average battery current
13.26 µA
Load, regulator and self-discharge
Self-discharge, as a current
267 nA
Usable capacity
211.5 mAh
Active duty cycle
0.2 %
Usable capacity remaining
0501001502000200400600Time (days)Capacity (mAh)
Method

How this is calculated

I_load = ( I_active · t_active + I_sleep · (T − t_active) ) / T
I_bat  = I_load + I_Q                          LDO
I_bat  = I_load · V_load / (η · V_bat) + I_Q   switching
I_sd   = C_rated · (self-discharge %/month) / 730.5 h
C_use  = C_rated · (1 − end-of-life %) · (1 − temperature %)
Life   = C_use / ( I_bat + I_sd )
Model
Constant average current drawn from a fixed charge, as in AN1416 Equation 4. Self-discharge is treated as an equivalent constant current on the rated capacity.
Derating
Both deratings are your inputs. Read end-of-life loss off the cell discharge curve at your minimum operating voltage, and temperature loss off the datasheet at your coldest condition. No chemistry curve is assumed.
Rated capacity
Capacity is specified at one load and cutoff. The Energizer CR2032 figure of 235 mAh is to 2.0 V on 15 kΩ at 21 °C. Higher pulse loads and lower cutoffs change it; check the datasheet curves.
Month
730.5 h, one twelfth of a 365.25 day year.
Sources
FAQ

Questions

Energizer rates its CR2032 at 235 mAh to 2.0 V on a 15 kΩ load, about 0.19 mA, which it gives as 1245 hours. At a 13 µA average, the default here, it lasts about 665 days once 10 % is set aside for end of life and 1 % per year of self-discharge is counted.

Multiply each state's current by its time, add them, and divide by the cycle length. 5 mA for 20 ms every 10 s with 3 µA asleep averages 13 µA, of which sleep is 3 µA, about a quarter. Over years asleep that quarter is real capacity, so measure it.

At low average currents it does. 1 % per year on 235 mAh is an equivalent drain of about 0.27 µA. Microchip AN1416 shows a CR2032 sensor lasting 8.3 years with it included.

Yes. An LDO passes the load current straight through and adds its quiescent current, so a 1 µA part adds 1 µA to every hour of sleep. A switcher scales the load by the voltage ratio and its efficiency at that load, which is often poor at microamps.